(Intermediate Polarity Deactivated) Use in a wide variety of applications / Allow most common solvents (Polar Deactivated) Provide optimum wettability for polar compounds / Minimize peak splitting and peak tailing when using polar solvents such as water or methanol / Polyethylene glycol deactivation used for DM-Wax, DM-225 and DM-2330 (Water Resistant Deactivated) High-density surface deactivation and excellent water resistance / Use for purge / trap system, headspace injection, gas concentration analysis and hydrated sample test / Inertness and water resistance tube connection (Base Deactivated) Excellent inertness for basic compounds / Use for DM-5 Amine, DM-35 Amine, DM-Wax Amine, DM-Volatile Amine / Batch test with basic compounds .

100% Dimethyl polysiloxane / General purpose column of non-polar phase / Long lifetime / Temperature range: -60 ºC to 350 ºC / Bonded and cross-linked phase, solvent rinsable / DM-1MS is a low bleed column, use for MSDs / Similar to DB-1, SPB-1, HP-1, etc. / Equivalent to USP G1, G2, G38 phases.
.png)
DM-1MS column exhibits ultra-low bleed that has excellent inertness for active compounds and improves detection performance for MSDs, ECDs and NPDs.
DM-1 100% Dimethyl polysiloxane HP-1, DB-1, CP-Sil 5CB DM-1HT 100% Dimethyl polysiloxane DB-1ht, VF-1ht DM-1MS100% Dimethyl polysiloxane (low bleed) HP-1, HP-1ms, DB-1, DB-1ms, Ultra 1, VF-1ms, CP-Sil 5 CB Low Bleed / MS DM-5 5% Diphenyl 95% Dimethyl polysiloxane DM-5HT 5% Diphenyl 95% Dimethyl polysiloxane DB-5ht, VF-5ht DM-5MS 5% Diphenyl 95% Dimethyl polysiloxane (low bleed) HP-5, HP-5ms, DB-5, Ultra 2, CP-Sil 8 CB HP-5, DB-5, CP-Sil 8 CB DM-5MS / LB 5% Diphenyl 95% Phenyl arylene dimethyl polysiloxane (low bleed) DB-5ms, DB-5ms UI, VF-5ms, CP-Sil 8 CB Low Bleed / MS .
6% Cyanopropylphenyl / 94% dimethyl polysiloxane / Recommended in US EPA methods for volatile organic pollutants / Ideal for analyzing residual solvents in drugs / Stable up to 240 ºC / Solvent rinsable / Similar to HP-1301, HP-624, DB-1301, DB-624, etc. / Equivalent to USP G43 phase .
Polyethylene glycol / Specially designed for analysis of FAMEs / Tested with a FAME mixture / Stable up to 250 ºC / Similar to Omegawax / When DM-FAMEWAX is used for separation of unsaturated FAMEs, the baseline resolution is achieved in less time above image.
Typical GC methods for analysis of basic compounds require derivatization to avoid peak tailing. The DM-35 Amine column has a special tubing surface which is chemically altered to reduce tailing of basic compounds, thereby eliminating the need for column priming. The DM-35 Amine column is ideal for analysis of basic compounds including alkylamines, diamines, triamines, ethanolamines, nitrogen heterocyclic compounds, neutral compounds and adsorptive compounds with oxygen groups susceptible to hydrogen bonding, or even weakly acidic compounds such as phenols. Every DM-35 Amine column is tested to ensure that it meets the requirements for analyzing amines with low ppm levels, and to ensure low bleed at maximum operating temperature .